English 中 文 日本語
 
 

400E10TR-1T ultrasonic sensor for anemometer


SCOPE


This specification includes 400E10TR-1T ultrasonic sensor size, characteristics, performance parameters and precautions, before using this product, please read this specification. 400E10TR-1T has the functions of transmitter and receiver. It’s a unit for ultrasonic anemometer with 4pcs ultrasonic wind sensors, intelligently measure wind speed and direction, widely be used in meteorological monitoring, bridges, tunnel, mine and mariners, etc. If you have any questions for other applications, please contact us for details.


PHOTO


CHARACTERISTICS

Part Number

400E10TR-1T

Construction

High Frequency

Using Method

Receiver and Transmitter (Dual use)

Nominal Frequency

400.0±16.0KHz

Bandwidth

40.0KHz

Sensitivity

-75dB min.

Min. Parallel Resistance

600Ω±30%

Capacitance

180Pf±20%

Max. Input Voltage

300Vp-p

Directivity

15°±2°(-6dB)

Distance of Detection

0.050.3m

Protection Level

IP67

Operating Temperature

-40+80

Storage Temperature

-40+85

Material of Cover

Aluminum Alloy


FEATURES OF OSENON ULTRASONIC SENSOR


1, Small size and light-weight

2, High sensitivity and high sound pressure

3, Low power consumption

4, High reliability


NOTICE IN USE AND STORAGE


1
, Please do not apply D.C.voltage for ultrasonic sensors to avoid migration.

2, Because the sensors have potential direction, please pay attention to its installation location.

3, To ensure reliability and long service life, do not use the sensors where temperature is higher than rated.

4, Can not use the sensors in a vacuum zone or hazardous areas.

5, Do not use in a steam zone, this area of the atmosphere produce uneven temperature gradient will lead to measurement error.

6, The products should not be used or stored in a corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali, salt or the like are present. Store the products in the room where is normal temperature and humidity, and avoid the sunlight, sudden changes in temperature and humidity. It may cause of failure or malfunction in such conditions.

7, If you will apply to non-standard frequency and other special conditions, please inform us the specific work conditions, the circuit you need, in order to make sensors to meet your specific requirements.


STATEMENTS

1, No OSENON products should be used or sold for use in the design, utilization, maintenance, operation or contribution to any weapons such as nuclear, chemical or biological weapons or missiles etc.

2, Please contact our sales representatives or product engineers before using the product in this catalog for the applications listed below, which require especially high reliability for the prevention of defects which might directly damage a third party’s life, body or property:

Aircraft equipment Aerospace equipment Undersea equipment Power plant equipment Medical equipment Transportation equipment(vehicles, trains, ships, etc.) Traffic signal equipment Disaster prevention/ crime prevention equipment Data-processing equipment Application of similar complexity and/or reliability requirements to the applications listed above.

3, OSENON technical team constantly improve the technical, we reserve the right to change the appearance or product specifications without notice. Please pay attention to OSENON's website for the latest news.

Home | About Us | Products | Applications | Solutions | Contact Us
For more information, please contact us online at:eric@osenon.com
CopyRight © 2011 ShenZhen OSENON Technology Co.,Ltd. All rights reserved.粤ICP备11047462号